{"id":209,"count":0,"description":"PLASTICS \u2013 Determination of Carbon Black Content in Polyolefins\u2026\r\nThis test method covers the determination of carbon black content in polyethylene, polypropylene, and polybutylene plastics. Not recommended for use with acrylic modifications or other polar monomers that may affect precision. Carbon black content determinations are made gravimetrically after pyrolysis of the sample under nitrogen. This test method is not applicable to compositions containing non-volatile pigments or fillers other than carbon black.","link":"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/","name":"ASTM D1603","slug":"astm-d1603","taxonomy":"astm","parent":633,"meta":[],"acf":[],"aioseo_head":"\n\t\t<!-- All in One SEO 4.9.9 - aioseo.com -->\n\t<meta name=\"description\" content=\"PLASTICS \u2013 Determination of Carbon Black Content in Polyolefins\u2026 This test method covers the determination of carbon black content in polyethylene, polypropylene, and polybutylene plastics. Not recommended for use with acrylic modifications or other polar monomers that may affect precision. Carbon black content determinations are made gravimetrically after pyrolysis of the sample under nitrogen. This test method is not applicable to compositions containing non-volatile pigments or fillers other than carbon black.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 4.9.9\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/techlabsystems.com\\\/eng\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/products\\\/#listItem\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/products\\\/#listItem\",\"position\":2,\"name\":\"Products\",\"item\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/products\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/d-e-f\\\/#listItem\",\"name\":\"D-E-F\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/d-e-f\\\/#listItem\",\"position\":3,\"name\":\"D-E-F\",\"item\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/d-e-f\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/astm-d1603\\\/#listItem\",\"name\":\"ASTM D1603\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/products\\\/#listItem\",\"name\":\"Products\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/astm-d1603\\\/#listItem\",\"position\":4,\"name\":\"ASTM D1603\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/astm\\\/d-e-f\\\/#listItem\",\"name\":\"D-E-F\"}}]},{\"@type\":\"CollectionPage\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/#collectionpage\",\"url\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/\",\"name\":\"ASTM D1603 - Techlab Systems\",\"description\":\"PLASTICS \\u2013 Determination of Carbon Black Content in Polyolefins\\u2026 This test method covers the determination of carbon black content in polyethylene, polypropylene, and polybutylene plastics. Not recommended for use with acrylic modifications or other polar monomers that may affect precision. Carbon black content determinations are made gravimetrically after pyrolysis of the sample under nitrogen. This test method is not applicable to compositions containing non-volatile pigments or fillers other than carbon black.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/#breadcrumblist\"}},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/#organization\",\"name\":\"Techlab Systems\",\"description\":\"Equipment for quality control tests\",\"url\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/\",\"telephone\":\"+34943470007\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2021\\\/04\\\/Techlabsystems-identidad-en.svg\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/#organizationLogo\",\"width\":677,\"height\":133},\"image\":{\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/wp-json\\\/wp\\\/v2\\\/astm\\\/209\\\/#organizationLogo\"}},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/#website\",\"url\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/\",\"name\":\"Techlab Systems\",\"description\":\"Equipment for quality control tests\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/techlabsystems.com\\\/eng\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"ASTM D1603 - Techlab Systems","description":"PLASTICS \u2013 Determination of Carbon Black Content in Polyolefins\u2026 This test method covers the determination of carbon black content in polyethylene, polypropylene, and polybutylene plastics. Not recommended for use with acrylic modifications or other polar monomers that may affect precision. Carbon black content determinations are made gravimetrically after pyrolysis of the sample under nitrogen. This test method is not applicable to compositions containing non-volatile pigments or fillers other than carbon black.","canonical_url":"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BreadcrumbList","@id":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng#listItem","position":1,"name":"Home","item":"https:\/\/techlabsystems.com\/eng","nextItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/products\/#listItem","name":"Products"}},{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/products\/#listItem","position":2,"name":"Products","item":"https:\/\/techlabsystems.com\/eng\/products\/","nextItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/#listItem","name":"D-E-F"},"previousItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/#listItem","position":3,"name":"D-E-F","item":"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/","nextItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/#listItem","name":"ASTM D1603"},"previousItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/products\/#listItem","name":"Products"}},{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/#listItem","position":4,"name":"ASTM D1603","previousItem":{"@type":"ListItem","@id":"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/#listItem","name":"D-E-F"}}]},{"@type":"CollectionPage","@id":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/#collectionpage","url":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/","name":"ASTM D1603 - Techlab Systems","description":"PLASTICS \u2013 Determination of Carbon Black Content in Polyolefins\u2026 This test method covers the determination of carbon black content in polyethylene, polypropylene, and polybutylene plastics. Not recommended for use with acrylic modifications or other polar monomers that may affect precision. Carbon black content determinations are made gravimetrically after pyrolysis of the sample under nitrogen. This test method is not applicable to compositions containing non-volatile pigments or fillers other than carbon black.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/techlabsystems.com\/eng\/#website"},"breadcrumb":{"@id":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/#breadcrumblist"}},{"@type":"Organization","@id":"https:\/\/techlabsystems.com\/eng\/#organization","name":"Techlab Systems","description":"Equipment for quality control tests","url":"https:\/\/techlabsystems.com\/eng\/","telephone":"+34943470007","logo":{"@type":"ImageObject","url":"https:\/\/techlabsystems.com\/eng\/wp-content\/uploads\/sites\/2\/2021\/04\/Techlabsystems-identidad-en.svg","@id":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/#organizationLogo","width":677,"height":133},"image":{"@id":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209\/#organizationLogo"}},{"@type":"WebSite","@id":"https:\/\/techlabsystems.com\/eng\/#website","url":"https:\/\/techlabsystems.com\/eng\/","name":"Techlab Systems","description":"Equipment for quality control tests","inLanguage":"en-US","publisher":{"@id":"https:\/\/techlabsystems.com\/eng\/#organization"}}]}},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/techlabsystems.com\/eng\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/techlabsystems.com\/eng\/products\/\" title=\"Products\">Products<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/\" title=\"D-E-F\">D-E-F<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tASTM D1603\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/techlabsystems.com\/eng"},{"label":"Products","link":"https:\/\/techlabsystems.com\/eng\/products\/"},{"label":"D-E-F","link":"https:\/\/techlabsystems.com\/eng\/astm\/d-e-f\/"},{"label":"ASTM D1603","link":"https:\/\/techlabsystems.com\/eng\/astm\/astm-d1603\/"}],"_links":{"self":[{"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm"}],"about":[{"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/taxonomies\/astm"}],"up":[{"embeddable":true,"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/astm\/633"}],"wp:post_type":[{"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/product?astm=209"},{"href":"https:\/\/techlabsystems.com\/eng\/wp-json\/wp\/v2\/normas?astm=209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}